Time:2026-09-30 Browse: 95
Model: JJY-YLD128SP — 80 GHz radar level transmitter with display
The ranging result shows the radar reporting “within blind zone”.
The working condition produced a weak reflection signal, so the returned data fell into the antenna blind zone.
Change the installation to suspended mounting (keep the antenna away from the surface and obstructions) and set the blind zone to 0.3 m. The issue was resolved.


At a glance: when the display shows “within blind zone” the reflection is too close to the antenna to measure. A weak reflection placed the data inside the blind zone; suspended mounting and a 0.3 m blind-zone setting resolve it.
Hanging the sensor below the bracket moves the surface reflection out of the near-field blind zone.
Match the blind-zone parameter to the real minimum measuring distance so valid echoes are accepted.
For weak targets, increase RF power or reposition to a flatter surface.
For persistent issues on this topic, review the Jiajia Eye 80 GHz radar level transmitter range, or send our application engineers your tank drawing and process data for a free configuration check.