Process Measurement Guide
Continuous Level Measurement
Continuous level measurement shows the real-time height of solids or liquid inside a vessel so automated lines can dose, fill and discharge without stopping. Here is how the technologies compare and which to choose.
01 · Why it matters
What Continuous Level Measurement Does
- Tells you how much material is in a vessel right now—powder in a hopper, grain in a bin, liquid in a tank—without stopping the process.
- Feeds automated dosing, filling and discharge: the controller opens or closes a valve, starts a screw feeder, or trips an alarm at set points.
- Replaces manual dip-tape checks that are slow, unsafe on live process lines, and blind to what happens between readings.
- Drives inventory and production planning when every bin reports its level to one dashboard.
02 · Technologies
Four Ways to Measure Level
- 80 GHz radar (non-contact). A narrow beam reflects off the surface; unaffected by dust, vapour or coating. Our 80 GHz radar level sensors read hoppers, bins and silos through dust and turbulence.
- Guided-wave radar. A probe runs into the medium; good for still liquids and small tanks, but the probe contacts the product.
- Ultrasonic. Sound pulse off the surface; cheap, but dust, steam and foam attenuate it—see our radar vs ultrasonic comparison.
- Load cell / weight. Weighs the whole vessel; accurate for total mass but not for level in tall, narrow silos with uneven fill.
03 · Accuracy
What Moves the Number
- Beam angle. A wide beam reads the wall or the pile, not the true surface—see our beam-angle and silo-wall distance guide.
- Surface profile. Conical piles, crusting and bridging distort the echo return.
- Dielectric & mounting. Off-centre nozzles and nearby internals create false echoes.
- Process noise. Vibration, filling dust and temperature swings all add error if the sensor cannot reject them.
04 · Recommended
Which Sensor, Which Media
80 GHz Radar
Bulk solids & dusty bins
Narrow 2°–3° beam clears the wall; reads through dust and turbulence. First choice for hoppers, bins and grain silos.
Guided-wave radar
Still liquids & small tanks
Probe-in-medium reading, stable on boiling or agitated liquid. Used where a non-contact beam would be blocked.
Ultrasonic
Clean, low-dust service
Low-cost for still water or clean tanks; avoid in heavy dust, steam or foam.
05 · Explore by application
Where to Go Next
06 · FAQ
Continuous Level Measurement — FAQ
Is radar better than ultrasonic for dust?
For dusty bulk solids—grain, cement, powder—yes. Ultrasonic is absorbed by airborne dust and foam; 80 GHz radar penetrates it. Our comparison guide shows the trade-offs.
Can one sensor cover both solids and liquids?
An 80 GHz non-contact radar handles both, but the antenna and process connection differ by application. Tell us the media, range and vessel and we size it.
How accurate is continuous measurement?
Our 80 GHz radars reach ±2 mm on clean surfaces. Real-world accuracy depends on beam angle, mounting and surface profile—covered in how radar level sensors work.